Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
1.
Arq. bras. cardiol ; 120(12): e20230408, dez. 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1527795

ABSTRACT

Resumo Fundamento: As doenças crônicas não transmissíveis (DCNT), também conhecidas como doenças crônicas de longa duração, são consideradas a principal causa de morte e incapacidade em todo o mundo, e os seis pilares da medicina do estilo de vida (nutrição, exercício, controle de tóxicos, manejo do estresse, saúde do sono e conexão social) desempenham um papel importante na gestão holística da sua prevenção e tratamento. Além disso, as diretrizes médicas são os documentos mais aceitos com recomendações para o manejo das DCNT. Objetivo: O presente estudo tem como objetivo analisar a ausência de pilares de estilo de vida nas principais diretrizes médicas brasileiras sobre as DCNT e identificar evidências na literatura que possam justificar sua inclusão nos documentos. Método: As diretrizes brasileiras foram selecionadas de acordo com as causas de morte mais relevantes no Brasil, informadas pelo Sistema de Informações sobre Mortalidade publicado pelo Ministério da Saúde em 2019. Os periódicos foram selecionados na biblioteca PUBMED de acordo com a doença e os pilares do estilo de vida não mencionados. Resultados: Causas relevantes de mortes no Brasil são o infarto agudo do miocárdio (IAM), o diabetes mellitus (DM) e as doenças pulmonares obstrutivas crônicas (DPOC). Foram identificadas seis diretrizes relacionadas a essas DCNT e todas abordam aspectos do estilo de vida, mas apenas uma, referente à prevenção cardiovascular, destaca todos os seis pilares. Apesar disso, uma pesquisa bibliográfica envolvendo mais de 50 artigos mostrou que há evidências de que todos os pilares podem ajudar no controle de cada uma dessas DCNT. Conclusão: Raramente os seis pilares do estilo de vida são contemplados nas diretrizes brasileiras para IAM, DM e DPOC. A revisão da literatura identificou evidências de todos os pilares do estilo de vida para oferecer uma abordagem holística para a gestão e prevenção das DCNT.


Abstract Background: Noncommunicable diseases (NCDs), also known as chronic diseases that are long-lasting, are considered the major cause of death and disability worldwide, and the six pillars of lifestyle medicine (nutrition, exercise, toxic control, stress management, restorative sleep, and social connection) play an important role in a holistic management of their prevention and treatment. In addition, medical guidelines are the most accepted documents with recommendations to manage NCDs. Objective: The present study aims to analyze the lack of lifestyle pillars concerning the major Brazilian medical guidelines for NCDs and identify evidence in the literature that could justify their inclusion in the documents. Method: Brazilian guidelines were selected according to the most relevant causes of death in Brazil, given by the Mortality Information System, published by the Brazilian Ministry of Health in 2019. Journals were screened in the PUBMED library according to the disease and non-mentioned pillars of lifestyle. Results: Relevant causes of deaths in Brazil are acute myocardial infarction (AMI), diabetes mellitus (DM), and chronic obstructive pulmonary diseases (COPD). Six guidelines related to these NCDs were identified, and all address aspects of lifestyle, but only one, regarding cardiovascular prevention, highlights all six pillars. Despite this, a literature search involving over 50 articles showed that there is evidence that all the pillars can help control each of these NCDs. Conclusion: Rarely are the six pillars of lifestyle contemplated in Brazilian guidelines for AMI, DM, and COPD. The literature review identified evidence of all lifestyle pillars to offer a holistic approach for the management and prevention of NCDs.

2.
Rev. bioét. (Impr.) ; 31: e2967PT, 2023. tab
Article in Portuguese | LILACS | ID: biblio-1449536

ABSTRACT

Resumo O termo de consentimento livre e esclarecido tem a função de informar o participante de pesquisas clínicas sobre a natureza da pesquisa e seus direitos, formalizando sua decisão de participar. Estudos indicam que esse documento é redigido de modo complexo, comprometendo a autonomia do participante. Para este trabalho, foram redigidos dois termos de consentimento da mesma pesquisa hipotética, com estilos de redação diferentes. Ambos os termos foram analisados pela ferramenta Coh-Metrix Port, que avalia métricas linguísticas e acessibilidade textual. A análise indicou que os textos são complexos e exigem alta escolaridade para serem entendidos. Esses achados reforçam a percepção de que, no Brasil, os termos de consentimento podem ter sua real função comprometida e apontam a importância de modificar sua forma de elaboração.


Abstract The informed consent form informs clinical research patients about the nature of the research and their rights, formalizing their decision to participate; however, studies show that this document is written in a complex manner, compromising patient autonomy. Two consent forms from the same hypothetical research were developed with different writing styles and analyzed by the Coh-Metrix Port tool, which evaluates linguistic metrics and textual accessibility. Results showed that both texts were complex and required high schooling level to be understood. These findings reinforce the perception that consent forms may have their real function compromised and point to the importance of changing its elaboration.


Resumen El formulario de consentimiento informado tiene la finalidad de mostrar la naturaleza de la investigación y sus derechos al participante de la investigación clínica para formalizar su decisión de participar en el estudio. Los estudios indican que la redacción de este documento es compleja, lo que compromete la autonomía del participante. Para este estudio se redactaron dos formularios de consentimiento de una misma investigación hipotética, con diferentes estilos de escritura. Para el análisis de ambos formularios se utilizó la herramienta Coh-Metrix Port, que evalúa las métricas lingüísticas y la accesibilidad textual. Los resultados apuntaron a que los textos son complejos, lo que requiere un alto nivel de educación para su comprensión. Estos hallazgos coinciden que, en Brasil, los formularios de consentimiento pueden tener su finalidad comprometida y señalan la necesidad de modificar su forma de elaboración.


Subject(s)
Clinical Protocols , Consent Forms/ethics , Ethics, Research , Informed Consent , Educational Status
3.
Rev. bioét. (Impr.) ; 28(3): 410-417, jul.-set. 2020.
Article in Portuguese | LILACS | ID: biblio-1137123

ABSTRACT

Resumo Este artigo busca identificar contribuições da bioética para enfrentar conflitos relacionados à tomada de decisão em tempos de pandemia. Trata-se de texto elaborado a partir de reflexões pessoais dos autores em diálogo com a literatura de diferentes perspectivas da bioética. Com fundamento em relatos históricos, argumenta-se que, durante epidemias, a sociedade passa a atuar em modo de excepcionalidade, o que exige argumentação mais apurada para se posicionar ante os conflitos que surgem. Analisam-se então diferentes vertentes teóricas - principialismo, personalismo, utilitarismo e bioética social -, recolhendo de cada uma elementos que podem nortear a tomada de decisão. Com base nessas contribuições, propõem-se parâmetros para a atuação dos profissionais da saúde, reconhecendo igual valor em cada vida humana, com o propósito de salvar o maior número de pessoas possível. Por fim, aponta-se para a responsabilidade de agentes políticos.


Abstract This article aims to identify the contribution of bioethics to resolve decision-making conflicts in healthcare in times of pandemic. The research was based on the authors' personal reflections in a dialogue with the literature and different bioethical perspectives. Historical accounts show that when a society is experiencing an epidemic it starts to function in a mode of social exceptionality, reinforcing the need for a more appropriate form of reasoning before the ethical conflicts that may arise from this situation. Some approaches to bioethics - principlism, personalism, utilitarianism and social bioethics - are briefly examined in order to obtain the elements for guiding the decision-making process. Finally, we suggest some parameters for health professionals, recognizing the value of all human lives, to save as many lives as possible.


Resumen Este artículo tiene como objetivo identificar la contribución de la bioética para hacer frente a los conflictos relacionados con la toma de decisiones en tiempos de pandemia. Se trata de un texto elaborado con base en las reflexiones personales de los autores en diálogo con la literatura de diferentes perspectivas de la bioética. Con base en los relatos históricos, se argumenta que, durante epidemias, la sociedad pasa a actuar en modo de excepcionalidad, lo que requiere una argumentación más precisa para posicionarse ante los conflictos que surgen. Se analizan entonces diferentes vertientes teóricas -el principialismo, el personalismo, el utilitarismo y la bioética social-, recogiendo de cada una los elementos que pueden orientar la toma de decisiones. Con base en dichas contribuciones, se proponen parámetros para la actuación de los profesionales de la salud, reconociendo el mismo valor en cada vida humana, con el propósito de salvar al mayor número posible de personas. Por fin, se apunta hacia la responsabilidad de los agentes políticos.


Subject(s)
Risk Groups , Bioethics , Coronavirus Infections , Ethical Theory , Personhood , Decision Making/ethics , Pandemics
4.
Arq. bras. cardiol ; 105(5): 493-502, Nov. 2015. tab, graf
Article in English | LILACS | ID: lil-765001

ABSTRACT

AbstractBackground:The recording of arrhythmic events (AE) in renal transplant candidates (RTCs) undergoing dialysis is limited by conventional electrocardiography. However, continuous cardiac rhythm monitoring seems to be more appropriate due to automatic detection of arrhythmia, but this method has not been used.Objective:We aimed to investigate the incidence and predictors of AE in RTCs using an implantable loop recorder (ILR).Methods:A prospective observational study conducted from June 2009 to January 2011 included 100 consecutive ambulatory RTCs who underwent ILR and were followed-up for at least 1 year. Multivariate logistic regression was applied to define predictors of AE.Results:During a mean follow-up of 424 ± 127 days, AE could be detected in 98% of patients, and 92% had more than one type of arrhythmia, with most considered potentially not serious. Sustained atrial tachycardia and atrial fibrillation occurred in 7% and 13% of patients, respectively, and bradyarrhythmia and non-sustained or sustained ventricular tachycardia (VT) occurred in 25% and 57%, respectively. There were 18 deaths, of which 7 were sudden cardiac events: 3 bradyarrhythmias, 1 ventricular fibrillation, 1 myocardial infarction, and 2 undetermined. The presence of a long QTc (odds ratio [OR] = 7.28; 95% confidence interval [CI], 2.01–26.35; p = 0.002), and the duration of the PR interval (OR = 1.05; 95% CI, 1.02–1.08; p < 0.001) were independently associated with bradyarrhythmias. Left ventricular dilatation (LVD) was independently associated with non-sustained VT (OR = 2.83; 95% CI, 1.01–7.96; p = 0.041).Conclusions:In medium-term follow-up of RTCs, ILR helped detect a high incidence of AE, most of which did not have clinical relevance. The PR interval and presence of long QTc were predictive of bradyarrhythmias, whereas LVD was predictive of non-sustained VT.


ResumoFundamento:A documentação de eventos arrítmicos (EA) em candidatos a transplante renal (CTR) submetidos à diálise é limitada pelo registro de eletrocardiograma convencional. Um monitoramento contínuo do ritmo cardíaco parece ser o procedimento mais adequado para a detecção automática de arritmia, contudo esse método não foi explorado anteriormente.Objetivo:O objetivo deste estudo foi investigar a incidência e os preditores de EA em CTR usando um gravador de eventos implantável, do inglês, “loop recorder implantável” (ILR).Métodos:Um estudo prospectivo observacional foi conduzido entre Junho/2009 a Janeiro/2011. Cem CTR ambulatoriais consecutivos foram submetidos ao ILR e acompanhados pelo menos por um ano. Uma regressão logística multivariada foi aplicada para definir os preditores de EA.Resultados:Durante o tempo médio de acompanhamento de 424 ± 127 dias, EA foram detectados em 98% dos pacientes, sendo que 92% deles tinham mais de um tipo de arritmia, a maioria não considerada potencialmente séria. Taquicardia atrial sustentada e fibrilação atrial ocorreram respectivamente em 7% e 13% dos pacientes; bradiarritmia em 25% e taquicardia ventricular (TV) não-sustentada ou sustentada em 57%. Ocorreram 18 óbitos, 7 por morte cardíaca súbita, 3 por bradiarritmias, 1 por fibrilação ventricular, 1 por infarto do miocárdio e 2 óbitos devido à causas desconhecidas. A presença de QTc longo (Razão de Probabilidade [RP] = 7,28; intervalo de confiança de 95% [IC] 2,01-26,35; p = 0,002) e duração do intervalo PR (RP = 1,05; IC 95%: 1,02-1,08; p < 0,001) foram associados independentemente a bradiarritmias. A dilatação ventricular esquerda (DVE) foi independentemente associada à TV não-sustentada (RP = 2,83; IC 95%: 1,01-7,96; p = 0,041).Conclusões:Em acompanhamento de médio prazo de CTR, o ILR detectou uma alta incidência de EA, a maioria sem relevância clínica. O intervalo PR e a presença de QTc longo foram preditivos de bradiarritmias e DVE de TV não‑sustentada.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Arrhythmias, Cardiac/diagnosis , Electrocardiography, Ambulatory/instrumentation , Kidney Transplantation , Arrhythmias, Cardiac/physiopathology , Equipment Design , Electrocardiography, Ambulatory/methods , Predictive Value of Tests , Prospective Studies , Renal Dialysis , Risk Assessment , Time Factors
5.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 22(3): 143-151, jul.-set. 2009. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-538323

ABSTRACT

Objetivo: Comparar o comportamento clínico-evolutivo de portadores de CDI por taquicardia ventricular (TV) sincopal ou parada cardíaca (PC) por TV/FV. Método: 585 pacientes foram submetidos a implante de CDI entre jan/2000 e jul/2005 para prevenção secundária de morte súbita cardíaca (MSC). Foram selecionados 415 pacientes de um banco de dados prospectivo, distribuídos em dois grupos: G1, com TV sincopal (n=318) e G2, com PC por TV/FV (n=97). As variáveis analisadas foram: idade, sexo, fração de ejeção do ventrículo esquerdo(FEVE), classe funcional de insuficiência cardíaca (CF IC), medicamentos, terapias de choque apropriadas (TCA) pelo CDI e óbitos. Para análise estatística...


Subject(s)
Humans , Male , Female , Middle Aged , Defibrillators, Implantable , Death, Sudden, Cardiac/prevention & control , Syncope/complications , Tachycardia, Ventricular/chemically induced
7.
Genet. mol. biol ; 32(3): 470-476, 2009. ilus, mapas, tab
Article in English | LILACS | ID: lil-522312

ABSTRACT

A recent substantial rearrangement of the 882 described eleutherodactyline frog species has considerably improved the understanding of their systematics. Nevertheless, many taxonomic aspects of the South American eleutherodactyline species remain unknown and require further investigation using morphological, cytogenetic and molecular approaches. In this work, the karyotypes of the Brazilian species Ischnocnema juipoca (Atibaia and Campos do Jordão, SP), Barycholos cf. ternetzi (Uberlândia, MG, and Porto Nacional, TO), and Pristimantis crepitans (Chapada dos Guimarães and São Vicente, MT) were analyzed using Giemsa staining, Ag-NOR labeling, and C-banding techniques. All individuals had a diploid number of 22 chromosomes, but the Fundamental Numbers were different among species. The herein described low chromosome number of Pristimantis crepitans is unique within this genus, suggesting that cytogenetically this species is not closely related either to its congeneric species or to Ischnocnema. In addition, karyotype differences, mainly in the NOR position, clearly distinguished the two Barycholos populations, besides indicating the existence of a so far undescribed species in this genus. A taxonomic review could clarify the systematic position of P. crepitans and verify the hypothetic new Barycholos species.


Subject(s)
Animals , Anura/genetics , Cytogenetics , Brazil , Chromosome Banding , Karyotyping , Nucleolus Organizer Region
8.
Arq. bras. cardiol ; 91(4): 274-280, out. 2008. graf, tab, ilus
Article in English, Portuguese | LILACS | ID: lil-496601

ABSTRACT

FUNDAMENTO: O benefício da estimulação cardíaca em pacientes portadores de cardiomiopatia hipertrófica (CMH) tem sido questionado, sendo escassas as pesquisas sobre este assunto no Brasil. OBJETIVO: Descrever a indicação, a resposta clínica, as complicações e a sobrevida relacionadas ao implante de marcapasso em pacientes portadores de CMH. MÉTODOS: Foram estudados, retrospectivamente, 39 pacientes portadores de cardiomiopatia hipertrófica (41 por cento do sexo masculino) submetidos a implante de marcapasso, no período de maio de 1980 a novembro de 2003. RESULTADOS: Houve 27 portadores da forma obstrutiva e 12 portadores da forma não-obstrutiva com média de idade de 46,4 anos (14-77 anos) seguidos por 6,4 ± 4,1 anos. As principais indicações para implante foram: bloqueio atrioventricular espontâneo ou induzido (54 por cento), refratariedade à terapêutica associada a gradiente elevado (33 por cento), suporte para terapia medicamentosa por bradicardia (8 por cento) e prevenção de fibrilação atrial (5 por cento). Houve melhora na classe funcional de 2,41±0,87 para 1,97±0,92 (p = 0,008), bem como redução do número de sintomas referidos, sem ter havido diferença na utilização da terapia medicamentosa. Não houve óbitos relacionados ao procedimento que, apesar de demonstrar-se seguro, não foi isento de complicações (6 pacientes - 15,4 por cento). Ocorreram três óbitos durante o seguimento, todos em pacientes mulheres, portadoras de fibrilação atrial e com evidências de deterioração funcional. Observou-se uma forte associação de piora clínica com surgimento de fibrilação atrial ou flutter. CONCLUSÃO: A estimulação cardíaca artificial em pacientes com CMH foi bem-sucedida, com evidências de alívio sintomático em pacientes portadores da forma obstrutiva. Não se observou melhora funcional para a forma não-obstrutiva.


BACKGROUND: The benefits of heart stimulation in hypertrophic cardiomyopathy (HCM) patients have been questioned. Research work available in Brazil on those benefits is scarce. OBJECTIVE: To describe the indication, clinical response, complications and survival time related to pacemaker implant in HCM patients. METHODS: Thirty-nine hypertrophic cardiomyopathy patients were studied (41 percent males) and submitted to pacemaker implant from May, 1980 through November, 2003. RESULTS: Twenty-seven patients presented obstructive hypertrophic cardiomyopathy, and 12, non-obstructive. Mean age was 46.4 years of age (range 14 - 77), with follow-up of 6.4 ± 4.1 years. Major indications for implant were: spontaneous or induced atrioventricular block (54 percent), refractoriness to therapeutic conduct associated to high gradient (33 percent), support for drug therapy to treat bradychardia (8 percent), and atrial fibrillation prevention (5 percent). Functional class was shown to improve from 2.41±0.87 to 1.97±0.92 (p = 0.008), and symptoms referred were reduced. No change was made in drug therapy administration. No procedure-related deaths were reported. Although shown to be safe, the procedure was not free from complications (6 patients - 15.4 percent). Three deaths occurred in the follow-up period - the three of them were atrial fibrillation female patients, with evidence of functional deterioration. A close association was observed between clinical condition worsening and the onset of atrial fibrillation or flutter. CONCLUSION: Cardiac pacing in HCM patients was successful, with evidence of symptoms relief in obstructive HCM patients. No functional improvement was observed in non-obstructive patients.


Subject(s)
Adolescent , Adult , Aged , Female , Humans , Male , Middle Aged , Young Adult , Cardiac Pacing, Artificial , Cardiomyopathy, Hypertrophic/therapy , Atrioventricular Block/therapy , Brazil/epidemiology , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/mortality , Cardiomyopathy, Hypertrophic/mortality , Cardiomyopathy, Hypertrophic/physiopathology , Epidemiologic Methods , Young Adult
9.
Arq. bras. cardiol ; 90(3): 177-184, mar. 2008. ilus, graf, tab
Article in English, Portuguese | LILACS | ID: lil-479618

ABSTRACT

FUNDAMENTO: A programação ideal da energia de choque do CDI deve ser pelo menos 10 J acima do limiar de desfibrilação (LDF), necessitando de técnicas alternativas quando o LDF é elevado. OBJETIVO: Avaliar o comportamento clínico dos portadores de CDI com LDF>25 J e a eficácia da terapêutica escolhida. MÉTODOS: Foram selecionados portadores de CDI, entre janeiro de 2000 e agosto de 2004 (banco de dados prospectivo), com LDF>25 J intra-operatório, e analisaram-se: características clínicas, FEVE, resgate de eventos arrítmicos pelo CDI e óbitos. RESULTADOS: dentre 476 pacientes, 16 (3,36 por cento) apresentaram LDF>25J. Idade média de 56,5 anos, sendo 13 pacientes (81 por cento) do sexo masculino. Quanto à cardiopatia de base 09 eram chagásicos, 04 isquêmicos e 03 com etiologia idiopática. A FEVE média dos pacientes foi 37 por cento e 94 por cento utilizavam amiodarona. O seguimento médio foi de 25,3 meses. Em 02 pacientes com LDF > Choque Máximo (CM), foi necessário implante de eletrodo de choque adicional (array), sendo mantido programação com CM em zona de FV (>182bpm) nos demais. Durante o seguimento 03 pacientes apresentaram 67 terapias de choque apropriadas (TCA) com sucesso. Ocorreram 07 óbitos sendo 5 por causas não cardíacas e 2 por insuficiência cardíaca avançada. Os pacientes que foram a óbito apresentaram níveis de LDF maiores (p=0,0446), entretanto sem relação com a causa dos mesmos tendo em vista que não ocorreram TCA sem sucesso. CONCLUSÃO: Nessa coorte de pacientes com CDI, a ocorrência de LDF elevado foi baixa, implicando terapêuticas alternativas. Houve associação com disfunção ventricular grave, entretanto sem correlação com as causas de óbito.


BACKGROUND: The ideal programming of the implantable cardioverter defibrillator (ICD) shock energy should be at least 10J above the defibrillation threshold (DFT), requiring alternative techniques when the DFT is elevated. OBJECTIVE: To assess the clinical behavior of ICD patients with DFT>25J and the efficacy of the chosen therapy. METHODS: Patients who had undergone ICD implantation between Jan/00 and Aug/04 (prospective database) and presented intraoperative DFT>25J were selected. The analyzed variables were: clinical characteristics, LVEF, rescue of arrhythmic events from ICD and causes of deaths. RESULTS: among 476 patients, 16 (3.36 percent) presented DFT>25J. The mean age was 56.5 years, and 13 patients (81 percent) were men. According to the baseline cardiomyopathy, 09 patients had Chagas' disease, 04 had ischemic cardiomyopathy and 03 had idiopathic cardiomyopathy. Mean LVEF was 0.37 and amiodarone was used by 94 percent of the patients. Mean follow-up (FU) period was 25.3 months. DFT was higher than maximum energy shock (MES) in 2 patients and it was necessary to implant an additional shock electrode (array). It was programmed MES in ventricular fibrillation zone of ICD therapy in the other patients. In the FU, 03 patients had 67 successful appropriate shock therapies (AST). There were 05 noncardiac and 02 heart failure deaths. The patients who died showed higher DFT levels (p=0.044) without correlation with death because there wasn't unsuccessful AST. CONCLUSION: In this cohort of ICD patients, the occurrence of elevated DFT (>25J) was low, leading to alternative therapies. There was an association with severe ventricular dysfunction, although without correlation to the causes of death.


Subject(s)
Female , Humans , Male , Middle Aged , Arrhythmias, Cardiac/therapy , Defibrillators, Implantable , Electric Countershock , Amiodarone/therapeutic use , Anti-Arrhythmia Agents/therapeutic use , Arrhythmias, Cardiac/drug therapy , Arrhythmias, Cardiac/mortality , Differential Threshold , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/standards , Electrophysiologic Techniques, Cardiac , Electric Countershock/standards , Follow-Up Studies , Prospective Studies , Tachycardia, Ventricular/therapy , Ventricular Fibrillation/therapy
10.
Arq. bras. cardiol ; 88(3): 258-264, mar. 2007. tab, ilus
Article in Portuguese | LILACS | ID: lil-451725

ABSTRACT

OBJETIVOS: Avaliar a incidência e a causa de choques de CDI em crianças e adolescentes e sua repercussão na qualidade de vida (QV). MÉTODOS: De março/1997 a fevereiro/2006, 29 pacientes (15,7±5,4 anos) foram submetidos a implante de CDI. Parada cardiorrespiratória recuperada (41,5 por cento), taquicardia ventricular sustentada (27,6 por cento) e profilaxia primária de morte súbita cardíaca (30,9 por cento) motivaram os implantes. O número de terapias foi avaliado por entrevista e pela telemetria dos CDI. A QV foi avaliada pela aplicação do questionário SF-36 e comparada à de indivíduos saudáveis. Empregou-se o método de Kaplan-Meier para análise da sobrevida livre de choques. RESULTADOS: Após 2,6±1,8 anos de seguimento, 8 (27,6 por cento) pacientes receberam 141 choques apropriados em razão de TV polimórfica (6) ou FV (2), e 11 (37,9 por cento) sofreram 152 choques inapropriados em razão de taquiarritmias supraventriculares (8) ou oversensing (3). A expectativa de sobrevida livre de choques apropriados foi de 74,2 por cento±9,0 após um ano, e de 66,7 por cento±10,7 após três anos. Observou-se diminuição da QV nos aspectos físicos (61,7±28,7), na vitalidade (64,7±19,1), na saúde mental (65,9±22,7) e nos aspectos emocionais (66,7±38,5). Medo e preocupações relacionados ao CDI foram referidos por todos os pacientes. CONCLUSÃO: A despeito da grande eficácia dessa terapêutica, a incidência elevada de choques interferiu na QV e na adaptação ao dispositivo.


OBJECTIVES: To analyze the incidence and causes of ICD therapies in children and young adults and verify their impact on the quality of life (QoL). METHODS: From March/1977 to February/2006, 29 patients (15.7±5.4 years old) were submitted to ICD implants. Aborted cardiac arrest (41.5 percent), sustained ventricular tachycardia (27.6 percent) and primary prophylaxis of sudden cardiac death (30.9 percent) indicated device therapy. The number of therapies was evaluated by interviewing patients and by ICD diagnostic data. The SF-36 questionnaire was used to measure the QoL and the results were compared to healthy population. The expectative of freedom from ICD therapies were estimated by the Kaplan-Meier method. RESULTS: After 2.6±1.8 years follow-up, 8 (27.6 percent) patients received 141 appropriate ICD shocks due to ventricular tachycardia (6) or ventricular fibrillation (2), and 11 (37.9 percent) patients received 152 inappropriate ICD shocks due to supraventricular tachyarrhythmias (8) or oversensing (3). Expectative of freedom from appropriate shocks was 74.2±9.0 percent and 66.7±10.7 percent after one and three years, respectively. Compared to healthy population, QoL decreased in physical function (61.7±28.7), vitality (64.7±19.1), mental health (65.9±22.7) and role-emotional domains (66.7±38.5). All patients referred fear and concern related to ICD use. CONCLUSION: Despite the efficacy of ICD therapies, the high incidence of appropriate and inappropriate shocks interfered in patients' QoL and adaptation to the device.


Subject(s)
Adolescent , Adult , Child , Child, Preschool , Female , Humans , Male , Arrhythmias, Cardiac , Defibrillators, Implantable/statistics & numerical data , Electric Countershock/statistics & numerical data , Quality of Life , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/therapy , Death, Sudden, Cardiac , Heart Arrest/complications , Heart Arrest/therapy , Kaplan-Meier Estimate , Surveys and Questionnaires , Tachycardia, Supraventricular/complications , Tachycardia, Supraventricular/therapy
11.
Arq. bras. cardiol ; 87(5): 649-657, nov. 2006. ilus, tab
Article in Portuguese, English | LILACS, SES-SP | ID: lil-439708

ABSTRACT

OBJETIVO: Pretende-se avaliar em pacientes com cardiomiopatia hipertrófica e risco de MSC, submetidos a implante de cardioversor-desfibrilador implantável (CDI): a) ocorrência de eventos arrítmicos; b) ocorrência de eventos clínicos e correlações com eventos arrítmicos; c) ocorrência de terapia de choque do CDI e correlações clínico-funcionais; d) preditores clínico-funcionais de prognóstico. MÉTODOS: Foram estudados 26 pacientes com cardiomiopatia hipertrófica e fatores de risco de MSC, submetidos a implante de CDI no período de maio de 2000 a janeiro de 2004 (seguimento médio = 20 meses). Quatorze pacientes (53,8 por cento) eram do sexo feminino e a idade média foi de 42,7 anos. Em 16 pacientes (61,5 por cento), a indicação do CDI foi para prevenção primária de morte súbita cardíaca, e em 10 (38,5 por cento), para prevenção secundária. Vinte pacientes (76,9 por cento) apresentavam síncope prévia ao implante de CDI, metade desses relacionados a fibrilação ventricular ou taquicardia ventricular sustentada; 15 (57,7 por cento) tinham história de morte súbita familiar; 12 pacientes (46,2 por cento), taquicardia ventricular não-sustentada ao Holter de 24 horas; e 5 (19,2 por cento) apresentavam o septo interventricular com espessura maior que 30 mm. RESULTADOS: No seguimento foram registrados no CDI 4 terapias de choque em arritmias potencialmente letais (3 pacientes com taquicardia ventricular sustentada e 1 paciente com fibrilação ventricular). Ocorreu um óbito por provável acidente vascular cerebral tromboembólico. Quatro pacientes tiveram recorrência de síncope sem evento arrítmico registrado pelo CDI. A análise estatística demonstrou significância da precocidade do choque do CDI em pacientes cujo septo interventricular tinha espessura maior que 30 mm. CONCLUSÃO: 1- ocorrência de eventos arrítmicos em 50 por cento dos pacientes: a maioria (62 por cento) foi taquicardia ventricular, sustentada (31 por cento) e não-sustentada (31 por cento); nos outros pacientes...


OBJECTIVE: It is controversial the correlation between complex ventricular arrhythmia of hypertrophic cardiomyopathy and cardiac sudden death (CSD). In patients with hypertrophic cardiomyopathy and at risk for CSD that have been undergone implantable cardioverter-defibrillator (ICD) implantation, we evaluated: a- occurrence of arrhythmic events; b- clinical event occurrence and its correlation with arrhythmic events; c- ICD shock therapy occurrence and clinical-functional correlation; d- prognosis clinical-functional predictors. METHODS: Twenty-six patients have been studied. They presented hypertrophic cardiomyopathy and risk factors for CSD. These patients underwent ICD implantation, period May, 2000 through January, 2004 (average follow-up - 19 months). Fourteen patients (53.8 percent) were female and the mean age was 42.7. Sixteen patients (61.5 percent) ICD was performed due to primary prevention for sudden death and ten (38.5 percent) secondary prevention. Twenty patients (76.9 percent) had had syncope, previus to ICD implantation, half of them associated with ventricular fibrillation or sustained ventricular tachycardia; 15 had had family sudden death; 12 patients (46.2 percent) presented non-sustained ventricular tachycardia at 24-hour Holter and 5 (19.2 percent) showed the ventricular septum thickness larger than 30 mm. RESULTS: During the follow-up, 4 shocks therapy were recorded by ICD in potentially lethal arrythmias (3 sustained ventricular tachycardia and 1 ventricular fibrillation). There was one death, due to likely stroke. Four patients had syncope recurrence, with no arrhythmic event recorded by ICD. The statistical analysis has showed precocity significance of ICD shock, in patients whose ventricular septum thickness was larger than 30 mm. CONCLUSION: 1- arrhythmic events have occurred in 50 percent of the patients. Most of those events (62 percent) were ventricular tachycardia, 31 percent sustained tachycardia and 31 percent non-sustained ...


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Arrhythmias, Cardiac , Cardiomyopathy, Hypertrophic/complications , Death, Sudden, Cardiac/etiology , Defibrillators, Implantable , Arrhythmias, Cardiac , Cardiomyopathy, Hypertrophic/therapy , Death, Sudden, Cardiac/prevention & control , Electrocardiography, Ambulatory , Follow-Up Studies , Predictive Value of Tests , Prognosis , Risk Factors
12.
REBLAMPA Rev. bras. latinoam. marcapasso arritmia ; 19(2): 112-117, abr.-jun. 2006. ilus, tab
Article in Portuguese | LILACS | ID: lil-438640

ABSTRACT

Objetivo: Avaliar a importância clínica da presença de marcapasso definitivo (MPD) previamente ao implante de CDI de nossa instituição, foram selecionados 275 submetidos a implante de CDI para prevenção secundária de morte súbita cardíaca (MSC), agrupados de acordo com a cardiomiopatia de base e a presença de MPD prévio ao implante de CDI. As variáveis analisadas foram: sexo, idade, CF-NYHAA, medicações, ritmo cardíaco, FEVE e TVNS. Para análise estatística, utilizou-se o método de Kaplan Meier e o teste de log-rank. Resultados: A amostra reduzida de pacientes com consistentes...


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Chagas Disease/complications , Chagas Disease/diagnosis , Death, Sudden/prevention & control , Pacemaker, Artificial/adverse effects , Pacemaker, Artificial
13.
REBLAMPA Rev. bras. latinoam. marcapasso arritmia ; 19(1): 45-52, jan.-mar. 2006. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-438633

ABSTRACT

Identificar marcadores de melhora clínica no subgrupo de pacientes com bloqueio completo de ramo esquerdo (BRE) da coorte submetida a ressincronização cardíaca (RC) no InCor-SP do HCFMUSP. Material e método: Foram analisadas características clínicas e epidemiológicas prospectivas de 121 pacientes com IC e BRE submetidos a RC. O critério de melhora clínica foi a redução de pelo menos duas classes funcionais (CF-NYHA) durante acompanhamento mínimo de seis meses. As variáveis analisadas pré e pós RC para comparação do comportamento dos grupos foram: CF-NYHA, sexo, idade, drogas, cardiopatia de base, ritmo cardíaco de base, BRE espontâneo X BRE induzido por marcapasso (troca de sistema ou primeiro implante), diâmetro diastólico final do ventrículo esquerdo (DdVE) e fração de ejeção do ventrículo esquerdo (FEVE - ecocardiograma). A análise estatística foi realizada por meio dos testes de Qui-Quadrado, exato de Fisher e regressão logística de Cox. Resultados: Houve redução de duas CF em 36 por cento dos pacientes e de uma CF em 54 por cento (inalterada em 10 por cento). Associaram-se à redução significativa da CF (análise univariada) o ritmo sinusal (p igual a 0,023), BRE espontâneo (p igual a 0,035), cardiomiopatia dilatada (CMD) (p igual a 0,03), não uso de amiodarona (p igual a 0,003) DdVE (p igual a 0,044). DdVE e CMD foram preditores independentes de melhora clínica (análise múltipla). conclusões: 1. A melhora clínica foi maior em pacientes com BRE espontâneo em relação ao BRE induzido. 2. As medidas dio DdVE e CMD discriminaram subgrupos de resposta clínica satisfatória (seguimento tardio) e foram preditores independentes deste comportamento.


Subject(s)
Humans , Male , Middle Aged , Cardiomyopathy, Dilated/complications , Cardiomyopathy, Dilated/diagnosis , Heart Failure/complications , Heart Failure/diagnosis , Ischemia/complications , Ischemia/diagnosis
14.
Article in Portuguese | LILACS | ID: lil-413381

ABSTRACT

Introdução: O Holter é o método diagnóstico com maior sensibilidade e especificidade para determinar os eventos arrítmicos. O uso do próprio sistema de estimulação como instrumento confiável de diagnóstico de arritmias cardíacas tem sido pouco relatado na literatura. Objetivo: analisar comparativamente os registros dos eventos arrítmicos realizados pelo marcapasso e Holter de 24 horas. Métodos: foram analisados 43 portadores de marcapasso Guidant da linha Pulsar Max câmara única e dupla, com idade variando entre 45 a 90 anos(média 71 anos) no período de janeiro de 2001 até junho de 2002. Todos os pacientes foram submetidos à monitorização pelo Holter de 24 horas e aos registros simultâneos pelo marcapasso. Foram analisados e comparados os seguintes parâmetros: registros de taquicardias atriais e ventriculares, número de batimentos estimulados e presença de extra-sístoles. Resultados: a correlação entre os eventos registrados pelo Holter e marcapasso foi encontrada somente em relação ao número de batimentos cardíacos estimulados e à presença de extra-sístoles(p menor 0,05). Conclusão: o marcapasso possui um sistema de armazenamento de eventos arrítmicos considerado eficiente apenas para documentação de números de extra-sístole e batimentos estimulados


Subject(s)
Humans , Male , Female , Middle Aged , Electrocardiography, Ambulatory/trends , Electrocardiography, Ambulatory , Cardiac Pacing, Artificial/methods , Cardiac Pacing, Artificial/trends , Cardiac Pacing, Artificial , Pacemaker, Artificial/trends , Pacemaker, Artificial , Heart Failure/diagnosis , Heart Failure/physiopathology
16.
Arq. bras. cardiol ; 78(1): 110-113, Jan. 2002. tab
Article in English | LILACS | ID: lil-301423

ABSTRACT

PURPOSE: To analyze the influence of biventricular pacing (BP) on clinical behavior, ventricular arrhythmia (VA) prevalence, and left ventricular ejection fraction (LV EF) by gated ventriculography. METHODS: Twenty-four patients with left bundle branch block (LBBB) and NYHA class III and IV underwent pacemaker implantation and were randomized either to the conventional or BP group, all receiving BP after 6 months. RESULTS: Sixteen patients were in NYHA class IV (66.6 per cent) and 8 were in class III (33.4 per cent). After 1-year follow-up, 14 patients were in class II (70 per cent) and 5 were in class III (25 per cent). Two sudden cardiac deaths occurred. A significant reduction in QRS length was found with BP (p=0.006). A significant statistical increase, from a mean of 19.13 ñ 5.19 per cent (at baseline) to 25.33 ñ 5.90 per cent (with BP) was observed in LVEF Premature ventricular contraction prevalence decreased from a mean of 10,670.00 ñ 12,595.39 SD or to a mean of 3,007.00 ñ 3,216.63 SD PVC/24 h with BP (p<0.05). Regarding the hospital admission rate over 1 year, we observed a significant reduction from 60. To 16 admissions with BP (p<0.05). CONCLUSION: Patients with LBBB and severe heart failure experienced, with BP, a significant NYHA class and LVEF improvement. A reduction in the hospital admission rate and VA prevalence also occurred.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Bundle-Branch Block , Cardiac Output, Low , Cardiac Pacing, Artificial , Bundle-Branch Block , Cardiac Output, Low , Prevalence , Prospective Studies , Stroke Volume
17.
Arq. bras. cardiol ; 76(1): 11-14, jan. 2001. ilus, tab
Article in Portuguese, English | LILACS | ID: lil-279894

ABSTRACT

OBJECTIVE: To assess the incidence of problems requiring reprogramming of atrioventricular pacemakers in a long-term follow-up, and also the causes for this procedure. METHODS: During the period from May '98 to December '99, 657 patients were retrospectively studied, An actuarial curve for the event reprogramming of the stimulation mode was drawn. RESULTS: The follow-up period ranged from 12 to 178 months (mean = 81 months). Eighty-two (12.4 percent) patients underwent reprogramming of the stimulation mode as follows: 63 (9.5 percent) changed to VVI,(R/C); 10 (1.5 percent) changed to DVI,C; 6 (0.9 percent) changed to VDD,C; and 3 (0.5 percent) changed to DOO. The causes for the reprogramming were as follows: arrhythmia conducted by the pacemaker in 39 (37.6 percent) patients; loss of atrial sensitivity or capture, or both, in 39 (38.6 percent) patients; and microfracture of atrial electrode in 5 (4.9 percent) patients. The stimulation mode reprogramming free probability after 15 years was 58 percent. CONCLUSION: In a long-term follow-up, the atrioventricular pacemaker provided a low incidence of complications, a high probability of permanence in the DDD,C mode, and the most common cause of reprogramming was arrhythmia conducted by the pacemaker


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Middle Aged , Cardiac Pacing, Artificial , Equipment Failure , Pacemaker, Artificial , Actuarial Analysis , Aged, 80 and over , Follow-Up Studies , Retrospective Studies
18.
REBLAMPA Rev. bras. latinoam. marcapasso arritmia ; 9(2): 92-6, maio 1996. ilus, tab
Article in Portuguese | LILACS | ID: lil-220035

ABSTRACT

A fim de avaliar o comportamento de sistemas VDD,C com único cabo-eletrodo quanto à eficiência, às condiçöes de manuseio e ao grau de segurança, foram estudados 13 pacientes. Sete eram do sexo masculino e a idade média foi de 57,5 anos. A indicaçäo de implante foi bloqueio atrioventricular (BAV) total em 7 e BAV do tipo em 6. Os exames realizados foram: teste de atropina, Holter de 24h, teste ergométrico e avaliaçäo eletrônica dos sistemas. O seguimento variou de 2 a 8 meses (média=5,1). Nenhum dos pacientes teve perda definitiva de comando do marcapasso: os dois casos de aumento do limiar de estimulaçäo foram corrigidos por reprogramaçäo. Em 4 pacientes ocorreu perda da sensibilidade atrial: em um deles a correlaçäo se fez por reprogramaçäo e em outro por cirurgia; dois casos persistiram com undersensing atrial interminente. Ocorreu ainda um de perda de sensibilidade ventricular, também corrigida por reprogramaçäo. Concluímos que o sistema VDD,C com único cabo-eletrodo em seguimento a curto prazo demonstrou: 1- eficiência quanto ao modo básico de operaçäo em todos os casos; 2- fácil manuseio, pois na maioria dos casos as complicaçöes puderam ser corrigidas através de reprogramaçäo; 3- segurança, pois näo ocorreram complicaöes que pusessem em risco a vida dos pacientes.


Subject(s)
Humans , Male , Female , Middle Aged , Adult , Adolescent , Heart Block , Pacemaker, Artificial , Evaluation Study , Follow-Up Studies , Ischemia , Chagas Cardiomyopathy , Syncope , Time Factors
20.
Arq. bras. cardiol ; 55(3): 189-194, set. 1990. tab
Article in Portuguese | LILACS | ID: lil-90640

ABSTRACT

Objetivo: Avaliar o comportamento do sistema de estimulaçäo de câmara única responsivo em freqüência dotado de sensor mecânico, em seguimento clínico tardio. Casuística e Métodos: No período de setembro de 1986 e abril de 1989, 70 pacientes foram submetidos a implante de marcapasso com biosensor mecânico. Em 64 (91,9%) do modelo implantado foi Activitrax I e em 6 (8,1%) Activitrax II. Trinta e um pacientes (44,4%) eram do sexo masculino e a média de idade foi de 51,2 anos. Cinqüenta e um pacientes (72,9%) submeteram-se a implante por bloqueio atrioventricular total, 11 (15,7%) por disfunsäo do nó sinusal, um (1,4%) por disfunçäo binodal e um (1,4%) para suporte terapêutico de arritmia. A etiologia foi chagásica em 31,4%, miocardiosclerótica da junçäo atrioventricular em 5,8%) e idiopática em 11,5%. O grupo foi submetido a avaliaçöes clínicas, eletrônicas do marcapasso e a exames complementares: ecocardiograma, ECG dinâmico, teste ergométrico e ergoespirométrico. O seguimento médio foi de 19,6 meses. Resultados: Avaliaçöes clínicas: melhora da classe funcional de ICC em 86% dos pacientes. Näo ocorreram síncopes ou óbitos de causa cardíaca. Ecocardiograma: melhora na fraçäo de ejeçäo em 42% dos pacientes. ECG dinâmico: resposta de freqüência adequada em 94,3% dos pacientes. Teste ergométrico: freqüência submáxima atingida em 65,6% (boa resposta cronotrópica). Ergoespirometria: melhora do consumo de oxigênio em 75% dos casos etudados. Avaliaçöes eletrônicas: ausência de disfunçäo do gerador, complicaçöes em 18% dos casos todas corrigidas por reprogramaçäo. Conclusäo. O sistema de estimulaçäo da camâra única dotado de sensor mecânico mostrou-se seguro, eficaz e apresentou baixo índice de complicaçöes


Purpose: To evaluate the behavior of single chamber stimulation system, rate responsive with vibration sensing, taking into consideration the results of long term clinical follow-up. Patients and Methods: From september 1986 to april 1989, 70 patients received pacemakers with vibration sensing. Sixty fou rpatients (91.9%) implan-ted Activitrax I model and six (8.1%) Activitrax II. Thirty-one (44.3%) were men and the mean age was 51.2 years. Fifty-one patients (72.9%) had complete atrioventricular block, 11 (15.7%) sinus node dysfunction, one (1.4%) sinus node and atrioventricular disease, and one (1,4%)for therapeutic support of arrhythmia. The etiology of these dysfunctions were Chagas' disease in 31.4%, myocardiosclerosis in 35.7%, post-operative in 15.6%, post-av node fulguration in 5.8% and idiopathic in 11.5%. The group was submitted to clinic and electronic evaluezion and laboratory examinations: echocardiogram, dynamic ECG, stress test and ergoespirometric test. The meanfollow-up as 19.6 months. Results: Clinic evaluations: decrease in congestive heart failure functional class in 86% of the patients. No recurrence of syncopes and no cardiac deaths. Echocardiogram: increase in ejection fraction in 42% of patients. Dynamic ECG: appropriate rate response in 94.3% of patients (good cronotropic response). Ergoespirometry: increase in oxygen consumption in 75% of studied cases, Electronic evaluation: absence of generator dysfunction; complications in 18% of cases, all corrected by reprogramation. Conclusion: The single chamber cardiac stimulation system with vibration sensing showed safety, efficacy and low rate of complications.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Adult , Middle Aged , Pacemaker, Artificial , Cardiac Pacing, Artificial , Heart Failure/therapy , Stroke Volume , Aged, 80 and over , Chagas Cardiomyopathy/therapy , Prospective Studies , Heart Defects, Congenital/therapy , Heart Rate
SELECTION OF CITATIONS
SEARCH DETAIL